27-1/8"depth
withhand!e_
27-1/8"de
profundidad
cor!maniia
Product dimensions
Grounded ebctricai outlet is require& See "Eiectricai
requirements"L
Proper gas supply connection must be available. See
as supply requirements" section.
\
\_'_ .................... 29-7/8" de encho
SG _'
cooktop
height
36" de
altura
hasta la
superfici
e de la
estufa
J
I
!
!
!
J
!
29-7/8" width
\\\\\\
46-7/8" overall
height
46-7/8" de ekura
total
Cabinet dimensions!
requirements
Check bcafion where range wHH be installed, The
range shouM be iocated for convenient use in the
kitchen. Recessed installations must provide complete
enclosure of the sides and rear of range.
All openings in the wall or floor where range is to be
installed must be sealed.
IMPORTANT: Some cabinet and building materials are
not designed to withstand the heat produced by the
oven for baking and self-cleaning. Check with your
builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain
other damage.
Contact a qualified floor covering installer to check
that the floor covering can withstand at least 200°F.
Use an insulated pad or 1/4" plywood under range if
installing range over carpeting,
Anti-t@ bracket
The floor-mounted anti-tip bracket must be installed.
To install the anti-tip bracket supplied see the anti-tip
Bracket template/instruction sheet.
Dimensiones del producto
Se requiere de un tomacorriente de conexion a tierra.
Ver "Requisitos electricos'L
Debe estar disponible la conexi6n de suministro de
gas adecuada. Ver "Requisitos de suministro de gas"L
Dimensienes!requis#es
dei gabinete
Revise el lugar donde se ha de instalar la estufa, La
estufa debe ser instalada en un lugar donde resulte
comodo usarla. La instalaci6n empotrada debe cubrir
completamente los lados y la parte trasera de la
estufa.
Deben sellarse todos los orificios en la pared o en el
piso donde se ha de instalar la estufa.
_MPORTA[NTE: AIgunos gabinetes y materiales de
construccion no estan dise_ados para resistir el calor
producido por el homo al hornear o desempenar la
funcion de autolimpieza. Consulte con su
constructor o distribuidor de gabinetes para 6
asegurarse de que los materiales usados no se
descoloraran, exfoliaran ni sufriran otros dafios,
Contacte a un instalador de revestimientos de pisos
calificado para verificar que el revestimiento del piso
pueda resistir al menos temperaturas de 20O°F.
Use una lamina aislada o de madera terciada
(plywood) de 1/4" debajo de la estufa si la estufa sera
instalada sobre piso alfombrado.
Sopo#e antivuelco
Debe instalarse el soporte antivuelco fijado al suelo.
Para instalar el soporte antivuelco qua viene con la
estufa ver la hoja de irlstruccior_es/plantilla del
soporte antivuelco.
13" max. upper cabinet depth
13" de profundidad maxima en _ _ -_
_clearance to top of cooktop, see _.
I _te _ael e-spacio m{nimo hasta la parte superior de la
T _ ...... -J_ superficiede la estufa, vet _.
I _8" o peTtin g
_ width
30-1/8" de ancho
de la ebertura
Do not pinch the power supply cord between the
range and the wall.
Do not seal the range to the side cabinets.
No presione el cord6n de alimentaci6n entre la
estufa y la pared.
No pegue la estufa e los gabinetes latereles.
If cabinet depth is greater than 24", oven frame
must extend beyond cabinet fronts by 1/2" rain.
Si la profundidad de! gabinete supera las 24", el
marco del horno debe extenderse 1 un minimo
de 1/2" mas a!la de los frentes del gabinete.
4-1/2"
_¢J-"_This shaded area recommended for installation of rigid gas pipe.
Flexible gas pipe and electrical outlet are recommended in either shaded area.
Esta area eombreada recomendada para la instalaci6n de un tubo de gas rigido.
Se recomienda un tubo de gas flexible y ur! tomacorriente en cualquiera de las @'eas eombreadas.
18" rain. vertica! clearance between
overhead side cabinet to countertop
-- both sides
Espacio vertical minimo de 18"
entre el gabinete superior y el
mostrador, a ambos lados.
2" rain. horizontal spacing to side
wall or other combustible material
above the cooktop -- both sides
Espacio minimo horizontal de 2"
sobre la superficie de la estufa
hasta la pared lateral o cualquier
otro material combustible, e
ambos lados.
24" rain. when bottom of wood or metal cabinet is
protected by not less than 1/4" flame retardaet
millboard covered with not less than No. 28 MSG
sheet steel, 0.015" stainless steel, 0.024" aluminum
or O.O20"copper.
30" rain. clearance between the top of the cooking
platform and the bottom of an unprotected wood or
metal cabinet.
rain. cuando la parte inferior del gabinete de
madera o metal esta protegida per ur! carton
retardante alas llamas no menor de 1/4" cubierto
a! menoe por una hoja de acero No. 28 MSG,
acero inoxidable de 0.015", aluminio de 0.024" o
cobre de O.O2O".
Un eepacio minimo de 30" entre la parte superior
de la plataforma para estufar y la parte inferior de
un gabinete no protegido de madera o metal