User Manual - Page 30

For PDP-425CMX.

Loading ...
Loading ...
Loading ...
30
Special Installation (Embedding in the wall)
A
A
A
X (Front of the unit)
<Viewed from Above>
<Viewed from the Right Side>
Operating Temperature Restrictions
Temperature in space X and Y
A: 0 mm to 370 mm 0 °C to 40 °C
* The same operating temperature restrictions apply to the speaker system (PDP-S44-LR).
Operating Temperature Restrictions for Upside-Down Installations
* Upside-down mounting is unavailable when embedding this device in a wall.
Y (Rear of the unit)
3.4.3 Embedding in the wall
Carefully read the following imformation before trying to embed the unit in a wall. Observe all the limitations specified
below.
Be sure to mount the unit so that twisting, bending, or other deformation of the unit does not exceed 4 mm.
(1) Embedding in walls with space provided behind the unit (no obstructions within a distance of 300 mm from the
back surface of the unit).
A
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
. The methods indicated by a large “X” must not be used.
Before attaching the unit to fittings, double-check that the thickness and height of the fittings,
and the number of bolts is correct.
(Also refer to “3.4.1 Mounting to fittings” (pg. 26).)