Loading ...
Loading ...
Loading ...
8
WARNING: SAFETY PRECAUTIONS
Do not use the grill until a leak test has been
performed.
WARNING:
TEST FOR LEAKS
A complete gas tightness check must
be performed at the installation site.
To prevent fire or explosion hazard, DO NOT
use or permit sources of ignition in the area
while performing a leak test. Perform leak
test outdoors only. Never perform a leak test
with fire or flame. DO NOT SMOKE WHILE
PERFORMING THE LEAK TEST.
• Create a soapy solution of equal parts mild
dishwashing detergent and water.
• Check to be sure all controls are in the OFF
position.
• Turn on the fuel supply. For natural gas, turn
manual shut-off valve handle 1/4 turn to align
with gas flow. For LP, turn cylinder valve knob
counterclockwise one full rotation.
• Apply soap solution generously on all
connections and fittings. See illustrations.
• If growing bubbles appear on any connection
point, IMMEDIATELY turn off the gas supply.
To stop a gas leak:
• Turn on control knobs to release pressure.
Turn controls OFF.
• Wash off soapy solution and towel dry.
• Tighten the loose joint and perform a new
leak test.
Important Safety Instructions
Professional Outdoor Grills & Cooktops
Natural Gas Leak
Test Points
LP Gas Leak
Test Points
Loading ...
Loading ...