SECTION 5 SE.vlcE.'s"rEc.. .r'O.MA'rto.
I ,I
u i
5E, WATER FLOW THROUGH THE SOFTENER VALVE
SERVICE CYCLE
VALVE OUTLET TOP
(SOFT WATER DISTRIBUTOR
POSITION
SWITCH
RESINTANK ._/s_
ILRESIN
B=D, f:'Y I
DISTRIBUTOR
Hard water enters the valve inlet port internal valve porting routes
the water down and out the top distributor, into the resin tank Hard
water is softened as it passes through the resin bed, then enters the
bottom distributor Soft water flows back into the valve and oul the
valve outlet, to the house soft water pipes
FILL CYCLE
FILL FLOW
VALVE CAM
POSITION ROTOR & DISC
SWITCH
VENTURI
FILL
(SOFT)
VALVE OUTLET"
(SOFT WATER
- VALVE INLET
i (HARD WATER)
To begin a regeneration, the solid slate timer energizes Ihe circuit
to the valve motor The valve motor rotates Ihe rotor and disc and
the valve cam untilthe positionswitch lever drops toopen the motor
circuit and positionthe valve in FILL As the roto_and disc rotates,
the port opens for SOFT water fill lhrough the venturi Fill flow
continues to the brine valve, and into the sal storage tank Soft
water is still available to the house lines