Swing Barrier User Manual
15
Gnd
Sec
10
Gnd
Fire alarm input
Close immediately when
cancel
11
Sec
(5) Auto SW1
12
SW1
Enter open signal input
Connect to access device
NO-SW1 COM-Gnd
13
Gnd
(6) Auto SW2
14
SW2
Exit open signal input
Connect to access device
NO-SW1 COM-Gnd
15
Gnd
(7) COM1485
16
A+
RS485 communication
Protocol docking
17
B
(8) RGB LED
18
R
Negative of LED red
Negative of LED green
Negative of LED blue
+12V for LED bar
Connect to LED bar
19
G
20
B
21
+12V
(9) POS Sensor1
22
1-1
left sensor
Close sensor
Right sensor
Connect to position sensor
of core in the master
machineflap /slide gate
only use two sensor(open
and close)
23
1-2
24
1-3
25
+12V
12V output for sensor
26
GND
(10) IR Sensor
27
IR1
Enter infrared sensor
Pinch infrared sensor
Exit infrared sensor
Control board alarm when
sensor be block
28
IR2
29
IR3
30
+12V
12V output for infrared
31
GND
(11) N1 Entry
Indicator 2
POS Sensor2
32
D2
Output for indicator of
master machine
D1 for enter direction
D2 for exit direction
Connect to indicator of
master machine
33
D1
34
GND
35
+12V
36
2-1
left sensor
Close sensor
Right sensor
Connect to position sensor
of core in the master
machineflap /slide gate
only use two sensor(open
and close)
37
2-2
38
2-3
39
+12V
12V output for sensor
40
GND
(12) N2
41
C1
Reader reserve a place
42
C2
43
C3
44
C4
45
R
Negative of LED red
Negative of LED green
Negative of LED blue
+12V for LED bar
Connect to LED bar
46
G
47
B
48
+12V
(13) M1 output
49
GND
Motor output for mater
machie
Connect to motor of
master machine
50
+24V