Hikvision DS-K3BC411X Value Swing Gate

Quick Start Guide - Page 13

For DS-K3BC411X.

PDF File Manual, 22 pages, Read Online | Download pdf file

DS-K3BC411X photo
Loading ...
Loading ...
Loading ...
Swing Barrier User Manual
12
2Access control device connect
Access control device send open signal to control board , gate will open immediately ,The relay
time of access control device must be set to 0-1 seconds.
Enter SW Exit SW
SW1 Gnd SW2 Gnd
2.4 Debugging instruction
1Check wireCheck whether the connection wire of the gate and the power line are properly
connected before power on. If there is any abnormality on the power supply process, check the
connection wires firstly;
2Function testAfter power on the machine will open- close, and open -close, this process is
machine self-check, after the sound from buzzer means finish self-check. Dont stand in the lane in
the process of self-check;
3The control board will give alarm if stand in the lane without swipe card ;if no response when
infrared sensor be block, please check if the infrared sensors are alignedUnder normal
circumstances, the red led of receive sensor is no bright when no blocked .If the red led of
receive sensor is always bright ,that means the sensors no shoot well ,please adjust to aligned.
4The relay time of access control device must be set to 0-1 seconds.
5When the valid card is swiped, the indicator light turn greenIf the indicator indicates
incorrect or turn off and alarm immediately when go into first sensor, This means that the signal
connection is opposite, exchange the open signal connect terminal of SW1 Gnd to SW2 Gnd
6Check and test carefully, running smoothly, no abnormal condition, no impact sound, etc;
Confirm motor is no idle; the indicator light is correct and the infrared pinch function is normal
before putting into use.
Main board
Access control device
NC NO COM NC NO COM
mark
SW1---NO
Gnd-----COM
SW2----NO
Gnd-----COM
Loading ...
Loading ...