The validity is an internal parameter that helps judge whether the device should keep
tracking or not. This parameter is the waing me level before the device stops tracking
when the validity is low. Larger value means longer waing me.
Wait to Lower Tracking Speed If Low Validity
The validity is an internal parameter that helps judge whether the PTZ channel should lower
the tracking speed or not. This parameter is the waing me level before the device lowers
the tracking speed when the validity is low. Larger value means longer
waing me.
5.
Oponal: Check Tuning Mode.
Note
Tuning mode is to display the informaon that helps debugging the funcon. This mode is
reserved for technical support.
6.
Click Save.
4.11 Set Rapid Focus
Rapid focus is a funcon to reduce me of focusing comparing with that of normal focusing. To use
the funcon, calibraon should be done rst. Rapid focus may not be supported by certain device
models.
Steps
1.
Go to
Conguraon → PTZ → Rapid Focus .
2.
Add scenes for calibraon.
1) Adjust the live image to a desired scene via PTZ control buons, and click Add.
2) Set the Rate and the Calibraon Point Amount of the added scene.
Note
More calibraon points may increase calibraon accuracy, but more focusing me is required.
The default amount is recommended.
3.
Select the scene to display the calibraon line.
A red line displays on live image.
4.
Adjust the length and
posion of the line by dragging its two endpoints.
Note
The red line is recommended to stay in the center of the scene and to cover ground at the same
me.
Double click the image to enter full screen mode.
5.
Click Start Calibraon .
Calibraon status displays on the live image.
6.
Repeat to add other scenes and complete the calibraon.
7.
Check Enable aer successful calibraon.
8.
Click Save.