6.2.7 Region Exing Detecon
Region exing detecon detects objects that exit from a predened virtual region.
Steps
1. Go to Smart Analysis → Smart Event Sengs → Perimeter Protecon .
2. Select a camera.
3. Click Region Exing.
Figure 6-8 Region Exing Detecon
4. Check Enable Region Exing Detecon.
5. Oponal: Check Save VCA Picture to save the captured region exing detecon pictures.
6. Follow these steps to set the detecon rules and detecon areas.
1) Select Arming Region. Up to 4 regions are selectable.
2) Set Sensivity. The higher the value is, the more easily the detecon alarm will be triggered.
Its range is [0-100].
3) Click Draw Region and draw a quadrilateral in the preview window.
7. Oponal: Draw the maximum size/minimum size for targets. Only the targets in the size ranging
from maximum size to minimum size will trigger line crossing detecon.
1) Click Max. Size/Min. Size.
2) Draw an area in preview window.
3) Click Stop Drawing.
8. Oponal: Select Target of Interest as Human Body or Vehicle to discard alarms which are not
triggered by human body or vehicle.
9. Set the arming schedule. Refer to
Congure Arming Schedule .
10. Set linkage acons. Refer to Congure Linkage Acons .
11. Click Apply.