C9 Barometric pressure sensor damaged. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit (ECU).
1)
CA Water flow above 9.2gpm. Disconnect the appliance and purge hydraulic circuit
to remove air.
1)
Install water flow restrictor.
1)
Check water pressure does not exceed 150psi
(section 3.2).
CE
4)
Excessive flue blockage detected during operation
due to excessive pressure on the siphon.
Appliance shuts down for safety.
Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Check exhaust pipes and terminals for obstructions
and reset the error.
Check if flue length is according to specification
(section 4.6) and reset the error.
Check if the air filter is dirty or clogged, clean or
replace it if needed.
Perform gas and air tuning ( section 8.11).
1)
CF
4)
Excessive flue blockage detected during operation
due to insufficient combustion air.
Appliance shuts down for safety.
Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Check air intake and exhaust pipes and terminals for
obstructions and reset the error.
Check if flue length is according to specification
(section 4.6) and reset the error.
Check if the air filter is dirty or clogged, clean or
replace it if needed.
Perform gas and air tuning ( section 8.11).
1)
E0 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
E1 Hot water temperature above 194 °F (90 °C).
Appliance burner cut off to prevent scalding and
reactivation after cooling down.
Disconnect the appliance and purge hydraulic circuit
to remove air.
If the problem persists:
Reduce setpoint temperature to minimize
temperature instabilities.
E3
4)
Flue gases temperature above 167 °F (75 °C)
(residential) / 194 °F (commercial) or 2 minutes
above 14F (6C).
Appliance burner cut off to prevent overheating.
Descale appliance ( section 7.3).
1)
Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Check sensor resistance [15] (section 11) and
replace the sensor if it is not according to
specification.
1)2)