Operating Instructions
51
Greentherm T9800 SE 160/199 – 6 720 816 815 (2022/01)
Touch the symbol until the display shows P9 Purge.
After 2 sec. the fan starts working to purge the exhaust
circuit.
The fan remains running until the Purge menu is exited, to do
so:
▶Touch the symbol .
6.6 Service menu - AU Technical Settings
Accessing the AU Technical Settings menu
▶Touch the symbol .
Display shows P4 Information.
Touch symbols or to select AU Technical
Settings menu.
▶Touch the symbol .
Display shows Technical Settings menu (password input).
Select the password. The password is 1886.
Technical Settings completed.
▶Touch the symbol .
Access to installer exclusive menus.
P7 - Gas Type (LPG, NG)
LM - Temperature Limited
RS - Recirculation Settings
PC - Cascading
CA - Combustion Adjust
PA - Water Actuator
PF - Bypass Valve
PE - Appliance Type
AB Region Selection
A4 Demonstration
P7 - Gas Type (LPG, NG)
For more information,
▶See section6.8.
LM Temperature Limited
Unlock the Temperature Limit
▶Touch the symbol .
Display shows following menu.
Unlocked
–Locked
The current selection is in green color.
Touch symbols or to select Unlocked.
▶Touch the symbol .
Touch the symbol to return to main menu.
RS Recirculation Settings
To define recirculation comfort level,
Touch the symbol .
Touch symbols or to define comfort level.
1
2
–...
9
Choosing a higher comfort level (9) will set the recirculation
water temperature closer to the set point defined on the
water heater. Choosing a lower value (1) will favor
efficiency at the expense of recirculation temperature
comfort.
Touch the symbol .
Touch the symbol to return to main menu.
PC Cascading
Use this menu only after installing the cascading kit
(7709003962).
Only a qualified technician can change this parameter.
To define cascading settings,
Touch the symbol .
Touch symbols or to move between menus.
State
–Off
–On
Mode (Only available if State On is selected.)
–Primary
–Secondary
For more information,
See Cascading kit installation manual.
CA Combustion Adjust
For more information,
See section 8.11.
PA Water Actuator
For more information,
See section 6.7.
PF Bypass Valve
To Enable or Disable bypass function.