Bosch T9800SE199 Greentherm 9800 Tankless Water Heater Without Pump & Wi-Fi

Installation and Operating Guide - Page 35

For T9800SE199.

PDF File Manual, 76 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Installation instructions
35
Greentherm T9800 SE 160/199 – 6 720 816 815 (2022/01)
4.8.1 Gas Line Sizing Tables for NATURAL GAS
For your convenience, see below for an excerpt from gas line sizing tables for a single NG appliance. For details, see the current NFPA
54.
Required input for 160000 / 199000 BTU/hr for the Greentherm T9800 SE. The gas supply system must be sized for the combined
total maximum BTU/hr load requirements of all gas appliances running simultaneously.
The tables below show the maximum capacity of the gas supply pipe in cubic feet per hour. Please contact your local gas supplier for
the energy content of the gas to determine the BTU/hr capacity. Use 1,000 BTU/cubic foot for rough estimations.
Table 11 Maximum pipe capacity in cubic feet of Natural Gas per hour for gas pressures of <2.0 psig (55" WC or 138 mbar) and a
pressure drop of 0.5" W.C. (1.25 mbar) based on 0.60 specific gravity gas).
Table 12 Maximum pipe capacity in cubic feet of Natural Gas per hour for gas pressures of <2.0 psig (55" WC or 138 mbar) and a
pressure drop of 3.0” W.C. (7.5 mbar) based on 0.60 specific gravity gas).
Table 13 Maximum pipe capacity in cubic feet of Natural Gas per hour for gas pressures of <2.0 psig (55" WC or 138 mbar) and a
pressure drop of 0.5" W.C. (1.25 mbar) based on 0.60 specific gravity gas).
* EHD = Equivalent Hydraulic Diameter. The greater the value of EHD, the greater the gas capacity of the tubing.
Nominal
Iron Pipe
Size, inches
Internal
Diameter
inches
Length of Black Iron Pipe (Schedule 40 Metallic Pipe), Feet
10 20 30 40 50 60 70 80 90 100
¾ 0.824 360 247 199 170 151 137 126 117 110 104
1 1.049 678 466 374 320 284 257 237 220 207 195
Initial Supply Pressure of 8.0" w.c. or Greater
Nominal
Iron Pipe
Size, inches
Internal
Diameter
inches
Length of Black Iron Pipe (Schedule 40 Metallic Pipe), Feet
10 20 30 40 50 60 70 80 90 100
½ 0.622 454 312 250 214 190 172 158 147 138 131
¾ 0.824 949 652 524 448 397 360 331 308 289 273
1 1.049 1790 1230 986 844 748 678 624 580 544 514
Initial Supply Pressure of 8.0" w.c. or Greater
Length of Corrugated Stainless Steel Tubing (CSST), Feet
EHD* 10 20 30 40 50 60 70 80 90 100
30 828 580 471 407 363 330 305 285 268 251
31 958 672 546 471 421 383 355 331 311 295
37 1,530 1,090 895 778 698 639 593 555 524 498
Loading ...
Loading ...
Loading ...