Zline ALP10UC48 Alpine Series 48 Inch Under Cabinet Ducted Hood with 500 CFM, LED Lights, Delay Off, Stainless Steel Baffle Filter, ETL in Stainless Steel

User Manual - Page 8

For ALP10UC48.

PDF File Manual, 22 pages, Read Online | Download pdf file

ALP10UC48 photo
Loading ...
Loading ...
Loading ...
87
Alpine Wall Electrical Connection
Alpine Wall Tools
Utility knife
Flathead and
Philips screwdrivers
Upper chimney
Stainless steel baffle filter
Ducting transition
Lower chimney
Range hood
Optional duct tube
Powered screwdriver
or drill
Measuring tape
Adjustable wrench
Pencil
Level
BEFORE INSTALLATION
ALPINE WALL MODELS
TOOLS NEEDED:
INCLUDED PARTS:
ELECTRICAL REQUIREMENTS
Contact a qualified electrical installer.
Assure that the electrical installation is adequate and in conformance with Na-
tional Electrical Code, ANSI/NFPA 70 — latest edition, or CSA Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition
and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrician determine that the ground path is adequate.
A 110~120V/60Hz, AC-only, fused electrical supply is required on a separate
15-amp circuit, fused on both sides of the line.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure that the range hood is
properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT: Save manual for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit
breaker) box through flexible armored or non-metallic sheathed copper cable.
A U.L. - or C.S.A. - listed strain relief must be provided at each end of the power
supply cable.
Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating
of the appliance as specified on the model/serial rating label. Wire sizes must
conform to the requirements of the National Electrical Code ANSI/NFPA 70 —
latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1
and C22. 2 No. 0-M91 - latest edition and all local codes and ordinances. A
U.L. - or C.S.A. - listed conduit connector must be provided at each end of the
power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
BEFORE INSTALLATION
ALPINE WALL MODELS
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269