234
(1) S1/S2/S1&S2 is channel configuration bus information.
(2) Area for decode data.
(3) ASCII code corresponding to the text data (when the data format is 9 bits and there is no parity bit, ASCII
code corresponds to lower 8 bits of data on the left side).
(4) Counter: Calculates the total number of frames and the percentage of ERR (parity error and stop bit error)
frames.
(5) Clear: Clear the counter data.
(6) Roller bar.
In the decode data area, the stop bit error data is displayed in yellow, and the decode error data is displayed in
red;