Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click Conguraon → Access Control → RS-485 .
Check Enable, and set the parameters.
Peripheral Type
Select a peripheral from the drop-down list according the actual situaon. You can select from
Card Reader, Extension Module, or Access Controller.
Note
Aer the peripheral is changed and saved, the device will reboot automacally.
RS-485 Address
Set the RS-485 Address according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
Baud Rate
The baud rate when the devices are communicang via the RS-485 protocol.
Output Type
If you select Access Controller as the peripheral type, you should set the parameter. The device
will output the card No. or the employee ID to the access controller.
Click Save to save the sengs.
10.6.12 Card Sengs
Set Card Security
Click Conguraon → Card Sengs → Card Type to enter the sengs page.
Set the parameters and click Save.
Enable NFC Card
In order to prevent the mobile phone from geng the data of the access control, you can
enable NFC card to increase the security level of the data.
Enable M1 Card
Enable M1 card and authencang by presenng M1 card is available.