FLUKE 291-U Arbitrary Waveform Generator and Manager, 100 MS/s, 1 Channel

User Manual for the Fluke 291-U Arbitrary Waveform Generator and Manager, 100 MS/s, 1 Channel - Page 16

For 291-U.

PDF File Manual, 162 pages, Read Online | Download pdf file

291-U photo
Loading ...
Loading ...
Loading ...
291, 292, 294
Users Manual
1-4
Specifications
Specifications apply at 18 to 28 ºC after 30 minutes warm-up, at maximum output into
50 .
Waveforms
Standard Waveforms
Sine, square, triangle, DC, positive ramp, negative ramp, sin(x)/x, pulse, pulse train,
cosine, haversine and havercosine.
Sine, Cosine, Haversine, Havercosine
Range: 0·1 mHz to 40 MHz
Resolution: 0·1 mHz or 10 digits
Accuracy: 10 ppm for 1 year
Temperature stability: Typically <1 ppm/ºC.
Output level: 2.5 mV to 10 V p-p into 50
Harmonic distortion: <0.15 % THD to 100 kHz;
<-60 dBc to 2
0 kHz
<-50 dBc to 1 MHz,
<-40 dBc to 10 MHz
<-30 dBc to 40 MHz
Non-harmonic spurious: <-60 dBc to 1 MHz,
<-60 dBc +6 dB/octave 1 MHz to 40 M
Hz
Square
Range: 1 mHz to 50 MHz
Resolution: 1 mHz or 8 digits
Accuracy: 10 ppm for 1 year
Output level: 2.5 mV to 10V p-p into 50
Rise and fall times: <8 ns
Triangle
Range: 0.1 mHz to 500 kHz
Resolution: 0.1 mHz or 10 digits
Accuracy: 10 ppm for 1 year
Output level: 2.5 mV to 10V p-p into 50
Linearity error: <0.1 % to 30 kHz
Ramps and sin(x)/x
Range: 0.1 mHz to 500 kHz
Resolution: 0.1 mHz (10 digits)
Accuracy: 10 ppm for 1 year
Output level: 2.5 mV to 10V p-p into 50
Linearity error: <0.1 % to 30 kHz