Group No. Funcon Color Name Descripon
D4 Yellow/Green SENSOR Door Contact
D5 Yellow/Gray BTN Exit Door
Wiring
4.2 Wire Normal Device
You can connect the terminal with normal peripherals.
The wiring diagram without secure door control unit is as follows.
Figure 4-2 Device Wiring
Note
●
You should set the face recognion terminal's Wiegand direcon to "Input" to connect to a
Wiegand card reader. If connects to an access controller, you should set the Wiegand direcon to
"Output" to transmit authencaon informaon to the access controller.
●
For details about Wiegand direcon sengs, see Seng Wiegand Parameters in Communicaon
Sengs.
●
The suggested external power supply for door lock is 12 V, 1 A. The suggested external power
supply for the Wiegand card reader is 12 V, 1A.
●
The suggested power cable's diameter: 22 AWG. The suggested other cable's diameter: 26 AWG.
●
Do not wire the device to the electric supply directly.
Warning
The face recognion terminal shall adapt an external listed Class 2 power supply with surge
protected funcon.
DS-K1T671 Series Face Recognion Terminal User Manual