Samsung AC048BNPDKC/TC Air Conditioner Floor Standing Digital Inverter Technology 6.0 HP

User Manual - Page 39

For AC048BNPDKC/TC. Also, The document are for others Samsung models: AC048BNPDKC

PDF File Manual, 66 pages, Read Online | Download pdf file

AC048BNPDKC/TC photo
Loading ...
Loading ...
Loading ...
39
English
Installation Procedure
5 Check that the flaring is correct, referring to the
illustrations below for examples of incorrect flaring.
2
1
3
Correct Inclined Damaged
surface
Cracked
Uneven
thickness
CAUTION
If the pipes require brazing ensure that OFN (Oxygen
Free Nitrogen) is flowing through the system.
Nitrogen blowing pressure range is 0.02 to 0.05 MPa.
Step 8 Connecting the refrigerant
pipes
Items Maximum allowable length [m]
Outdoor unit
models
AC030BXPDKC
AC036BXPDKC
AC
048BXPD*C
AC054BXPDNC
Main pipe (L1) 50 75
Max. height
difference between
outdoor and indoor
unit (h1)
30 30
n=1
Outdoor
L₁
indoor
h₁
Temper grade and minimum thickness of the
refrigerant pipe
Outer diameter [mm]
Minimum thickness
[mm]
Temper grade
ø6.35 0.7
C1220T-O
ø9.52 0.7
ø12.70 0.8
ø15.88 1.0
ø15.88 0.8
C1220T-1/2H OR
C1220T-H
ø19.05 0.9
ø22.23 0.9
1 Connect each assembly pipe to the appropriate valves on
the indoor and outdoor units and fasten the flare nuts.
2 As depicted in the illustration below, tighten the flare
nut manually, and then apply the following torque with a
torque wrench.
Indoor unit
Liquid side
service valve
Gas side
service valve
DB68-11731A-02_IBIM_PAC Mirage Cooling Only_TC_EN_.indd 39DB68-11731A-02_IBIM_PAC Mirage Cooling Only_TC_EN_.indd 39 2023-07-19 오전 9:52:162023-07-19 오전 9:52:16