En-14
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated. • Isthebreakerturnedon?
• Isthepowersupplyplugconnected?
• IstheONtimerset?Page10
The horizontal vane does not
move.
Are the horizontal vane and the vertical vane
installedcorrectly?
• Isthefanguarddeformed?
• Whenthebreakeristurnedon,thehorizontal
vanes’positionwillberesetinaboutaminute.
After the reset has completed, the normal hori-
zontalvanes’operationresumes.Thesameis
true in the emergency cooling operation.
The unit cannot be operated for
about 3 minutes when restarted.
This protects the unit according to instructions
from the microprocessor. Please wait.
Mist is discharged from the air
outlet of the indoor unit.
The cool air from the unit rapidly cools moisture
in the air inside the room, and it turns into mist.
The swing operation of the HORI-
ZONTAL VANE is suspended for a
while, then restarted.
This is for the swing operation of the HORIZON-
TAL VANE to be performed normally.
Theairowdirectionchanges
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
When the unit is operated in COOL or DRY
mode, if the operation continues with air blow-
ingdownfor0.5to1hour,thedirectionofthe
airowisautomaticallysettoupwardposition
to prevent water from condensing and dripping.
• In the heating operation, if the airow tem-
perature is too low or when defrosting is being
done, the horizontal vane is automatically set
to horizontal position.
The operation stops for about
10minutesintheheating
operation.
Outdoor unit is in defrost.
Since this is completed in max. 10 minutes,
please wait. (When the outside temperature is
toolowandhumidityistoohigh,frostisformed.)
The unit starts operation by
itself when the main power is
turnedon,buthasn’treceived
sign from the remote controller.
These models are equipped with an auto
restart function. When the main power is
turned off without stopping the unit with the
remote controller and is turned on again, the
unit starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to “Auto restart function”. Page10
The indoor unit discolors over
time.
• Althoughplasticturnsyellowduetotheinuence
of some factors such as ultraviolet light and
temperature, this has no effect on the product
functions.
The operation indicator lamp is
dim. The unit does not beep.
• IstheNIGHTmodeset? Page 9
Outdoor Unit
The fan of the outdoor unit does
not rotate even though the com-
pressor is running. Even if the
fan starts to rotate, it stops soon.
When the outside temperature is low during
cooling operation, the fan operates intermittently
tomaintainsufcientcoolingcapacity.
Waterleaksfromtheoutdoor
unit.
During COOL and DRY operations, pipe or pipe
connecting sections are cooled and this causes
water to condense.
In the heating operation, water condensed on
the heat exchanger drips down.
In the heating operation, the defrosting operation
makesiceformingontheoutdoorunitmeltand
drip down.
Whitesmokeisdischargedfrom
the outdoor unit.
In the heating operation, vapor generated by the
defrostingoperationlookslikewhitesmoke.
Symptom Explanation & Check points
Remote controller
The display on the remote
controller does not appear or it
is dim. The indoor unit does not
respond to the remote control
signal.
• Arethebatteriesexhausted? Page 5
• Is the polarity (+, -) of the batteries correct?
Page 5
Are any buttons on the remote controller of other
electricappliancesbeingpressed?
Does not cool or heat
The room cannot be cooled or
heatedsufciently.
• Isthetemperaturesettingappropriate?
Page 6
• Is the fan setting appropriate? Please change
fan speed to High or Super High. Page 7
• Aretheltersclean? Page 13
Is the fan or heat exchanger of the indoor unit
clean?
Page 13
• Arethereanyobstaclesblockingtheairinletor
outletoftheindoororoutdoorunit?
• Isawindowordooropen?
• It may take a certain time to reach the setting
temperature or may not reach that depending on
the size of the room, the ambient temperature,
andthelike.
• IstheNIGHTmodeset? Page 9
The room cannot be cooled
sufciently.
• Whenaventilationfanoragascookerisused
in a room, the cooling load increases, resulting
inaninsufcientcoolingeffect.
When the outside temperature is high, the cooling
effectmaynotbesufcient.
The room cannot be heated
sufciently.
When the outside temperature is low, the heating
effectmaynotbesufcient.
Air does not blow out soon in
the heating operation.
Please wait as the unit is preparing to blow out
warm air.
Airow
The air from the indoor unit
smells strange.
• Aretheltersclean? Page 13
Is the fan or heat exchanger of the indoor unit
clean? Page 13
• The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it out
with the air.
Sound
Crackingsoundisheard. This sound is generated by the expansion/con-
traction of the front panel, etc. due to change in
temperature.
“Burbling” sound is heard. This sound is heard when the outside air is
absorbed from the drain hose by turning on the
rangehoodortheventilationfan,makingwater
owinginthedrainhosetospoutout.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Mechanical sound is heard
from the indoor unit.
This is the switching sound in turning on/off the
fan or the compressor.
Thesoundofwaterowingis
heard.
This is the sound of refrigerant or condensed
waterowingintheunit.
Hissing sound is sometimes
heard.
• This is the sound when the ow of refrigerant
inside the unit is changed.
Timer
Weeklytimerdoesnotoperate
according to settings.
• IstheON/OFFtimerset?Page10
• Transmit the setting information of the weekly
timer to the indoor unit again. When the infor-
mation is successfully received, a long beep will
sound from the indoor unit. If information fails to
be received, 3 short beeps will be heard. Ensure
information is successfully received. Page 11
When a power failure occurs and the main power
turns off, the indoor unit built-in clock will be
incorrect.Asaresult,theweeklytimermaynot
worknormally.
Be sure to place the remote controller where
the signal can be received by the indoor unit.
Page 5
The unit starts/stops the opera-
tion by itself.
• Istheweeklytimerset? Page 11