Figure 2-2 Hole Posion and System Wiring
4.
Bury cables. Each lane buries 1 high voltage cable and 1 low voltage cable. For details, see the
system wiring diagram of step 3.
Note
●
High voltage: AC power input
Low voltage: interconnecng cable (communicaon cable and 24 V power cable) and network
communicaon cable
●
The supplied 24 V power cable length is 4 m and the
communicaon cable length is 4 m.
●
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
●
If you want to bury both of the AC power cord and the low voltage cable, the two cables
should be in separated conduits to avoid interference.
●
If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
●
The external AC power cord should be double-insulated.
●
The network cable must be CAT5e or the network cable has
beer performance.
DS-K3Y220(L)X Series Flap Barrier User Manual