Rinnai Tankless Water Heater Installation and Operation Manual 80
6.3 Flushing the Heat
Exchanger
This water heater includes a service indicated/
reminder (Service Soon, SS). When selected in
the parameter settings, an SS code will display
on the controller indicating that it is time to ush
and service the water heater. Failure to ush
the appliance will cause damage to the heat
exchanger. Damage caused by lime build-up is
not covered by the water heater’s warranty. Rinnai
strongly recommends installation of isolation
valves to allow for ushing of the heat exchanger.
1. Turn o󰀨 power at the controller.
2. Disconnect electrical power to the water
heater.
3. Close the shuto󰀨 valves on both the hot water
and cold water lines (V3 and V4).
4. Connect pump outlet hose (H1) to the cold
water line at service valve (V2).
5. Connect drain hose (H3) to the hot water line
at service valve (V1).
6. Pour four gallons of undiluted virgin, food
grade, white vinegar into pail.
7. Place the drain hose (H3) and the hose (H2)
to the pump inlet into the cleaning solution.
8. Open both service valves (V1 and V2) on the
hot water and cold water lines.
9. Operate the pump and allow the vinegar to
circulate through the water heater for at least 1
hour at a rate of four gallons per minute (15.1
liters per minute).
10. Turn o󰀨 the pump.
11. Rinse the vinegar from the water heater as
follows:
E. Remove the free end of the drain hose (H3)
from the pail. Place in sink or outside to
drain.
F. Close service valve (V2) and open shuto󰀨
valve (V4). Do not open shuto󰀨 valve (V3).
G. Allow water to ow through the water heat-
er for ve minutes.
H. Close shuto󰀨 valve (V4). When unit has
nished draining remove the in-line lter
at the cold water inlet and clean out any
residue. Place lter back into unit and open
valve (V4).
I. Close service valve (V1) and open shuto󰀨
valve (V3).
12. Disconnect all hose
13. Restore electrical power to the water heater.
Scale build-up will a󰀨ect the performance of the
water heater. Water should be treated. Rinnai
o󰀨ers Southeastern Filtration’s “ScaleCutter
Water Conditioning System” that o󰀨ers superior
lime scale prevention and corrosion control by
feeding a blend of scale control compounds into
the cold water supply.