Loading ...
Loading ...
Loading ...
Rinnai Tankless Water Heater Installation and Operation Manual 23
4.3.7 Installation Location Checklist
Use this checklist to ensure you have selected the correct location for the water heater.
The water heater is not exposed to corrosive compounds in the air.
The water heater location complies with the required clearances.
The planned combustion air and exhaust termination locations meet the required clearances.
The water supply does not contain chemicals or exceed total hardness that will damage the
heat exchanger.
A standard 3 prong 120 VAC, 60 Hz properly grounded wall outlet (for internal/indoor models)
or other 120 VAC, 60 Hz source is available.
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z221.3/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1
Loading ...
Loading ...
Loading ...