Rinnai Tankless Water Heater Installation and Operation Manual 49
3. Common Vent (Indoor Units Only. Direct Vent and Non-Direct/Room Air Vent)
Common venting allows multiple RInnai Tankless Water
Heaters to share the same vent system. When operating
multiple water heaters in a common venting system, it
is recommended to use Rinnai’s EZConnect™ cable
(purchased separately) which electronically connect two
water heaters so they function as one hot water source.
Do not common vent this water heater with any other water
heater or appliance.
Common Vent Maximum Equivalent Vent Lengths
Common vent equivalent lengths include polypropylene pipe (PP) or PVC in a back-to-back or inline
conguration.
For the table below:
Header is the main vent pipe into which sever-
al vents connect.
Vent Length is the distance from the end of the
header to the vent termination.
Maximum vent length starts at the end of the
header system.
Vent Length
Figure 49: Sample Inline, Freestanding
Conguration
Water Heater Model
# Water
Heaters
Max System Btu/hr
Vent Diameter
3 in. 4 in. 6 in.
RU199i (REU-N3237FF-US)
RU180i (REU-N2934FF-US)
2 398,000
360,000
65 ft
(20 m)
150 ft
(46 m)
150 ft
(46 m)
RU160i (REU-N2530FF-US)
RU130i (REU-N2024FF-US)
2 320,000
260,000
90 ft
(27 m)
150 ft
(46 m)
150 ft
(46 m)
Header
Figure 50
Table 21: Common Vent Maximum Vent Length