Shop Fox W1830 3-Speed Hanging Air Filter

User Manual - Page 18

For W1830.

PDF File Manual, 32 pages, Read Online | Download pdf file

W1830 photo
Loading ...
Loading ...
Loading ...
-16-
Model W1830 (For Machines Mfd. Since 4/15)
OPERATIONS
OPERATIONS
General
Turning.ON.&.OFF
When the air filter is connected to power, press
the ON SPEED button on the air filter control
panel or the remote control to turn the unit ON.
Note: The remote control communicates with
the air filter using infrared (IR) and must be
pointed directly at the air filter control panel to
work properly.
Changing.Air.Flow.Speeds
The air filter can be set to operate in three air
flow speeds—260 (LO), 362 (MED), and 409 CFM
(HI). CFM is the acronym for Cubic Feet per
Minute of air flow that is generated through the
air filter.
To cycle through the available speeds, press the
ON SPEED button on the control panel or remote
control repeatedly. This will illuminate the
corresponding lights on the control panel.
Setting.Timer
The air filter can be set for a timed performance
of 1, 2, or 4 hours. At the end of this time, the
air filter will automatically turn OFF.
To cycle through the available time settings,
press the TIME button on the remote
control repeatedly. This will illuminate the
corresponding lights on the control panel.
Filtering.Performance
When used in conjunction with an efficient
dust collection system, the Model W1830
removes most fine wood particles up to 1
micron from the air. This air filter is capable of
recirculating the air in a room measuring 20'
x 20' x 8' approximately 7.7 times an hour. We
recommend that the volume of air in your room
be recirculated 6–9 times an hour for the best
filtering effect.
Therefore, rooms with a larger volume may
require two or more air filters to achieve proper
filtering.
To.calculate.the.recirculating.rate.for.your.
shop.space,.do.these.steps:
1. Calculate the volume of air in your shop by
multiplying the length x width x height of
the room (see the example below). Then,
divide the volume by the speed (CFM) you
have chosen to operate the air filter. This
will give you how many minutes it takes to
recirculate the air in the room.
Example: The room measures 20' x 20' x 8'
and you are operating the air filter at 409
CFM (HI).
20' x 20' x 8'
= =
3200 ft
3
409 CFM 409 CFM
7.8 Minutes
=
60 Min.
7.8 Min.
7.7 Times per Hour
20' x 20' x 8'
= =
3200 ft
3
409 CFM 409 CFM
7.8 Minutes
=
60 Min.
7.8 Min.
7.7 Times per Hour
2. Calculate how many times per hour the
room volume is recirculated through the
air filter by dividing 60 minutes by the
circulating time from Step.1. This will give
you how many times an hour the air in the
room is recirculated through the air filter.
Ma chine.Storage
When the air filter is not in use, unplug the
power cord from the power source. Secure the
power cord away from potential hazards, such as
high traffic areas, sharp objects, heat sources,
harsh chemicals or fumes, damp areas, etc.
Loading ...
Loading ...
Loading ...