Ashley AP5000 36" Wall Mount Direct Vent Pellet Stove with 1000 sq. ft. Capacity, 28 lbs. Hopper

Owner’s Instruction and Operation Manual - Page 6

For AP5000.

PDF File Manual, 44 pages, Read Online | Download pdf file

AP5000 photo
Loading ...
Loading ...
Loading ...
6
© 2021 United States Stove Company
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home in
accordance with the clearances given below. For
safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in
clearance to combustibles may only be done by
means approved by a regulatory authority.
C
Side Wall
Back Wall
E
G
D
Ceiling
Mantle/Sill
Back Wall
F
C Side Wall To Stove 6” (152 mm)
D Front Of Stove 24” (607 mm)
E
Ceiling To Stove (allow
for fuel loading)
18” (457 mm)
F Floor (allow for brace)
8” (203 mm vent
must meet min.
ground clearances)
G Mantle/Sill 11” (279 mm)
MOBILE HOME REQUIREMENTS
WARNING! -
DO NOT INSTALL IN A SLEEPING ROOM
CAUTION! -
THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
The heater must be permanently attached to the
wall.
The heater must be electrically grounded to the
steel chassis of the mobile home with 8 GA copper
wire using a serrated or star washer to penetrate
paint or protective coating to ensure grounding.
When moving your mobile home, the heater
must be removed while the mobile home is
being relocated. After relocation, heater may be
reinstalled and securely fastened.
Check with your local building ofcials as other
codes may apply.
GENERAL INSTALLATION NOTES
Do not install heater where the exhaust will
terminate in a window well or any opening below
ground level.
Special precautions may be required to prevent
snow build-up within 12” of the air intake.
Clearances around heater must provide adequate
room for service, cleaning, and air circulation.
Residential Garage Installation: The heater shall
be located or protected so it is not subject to
damage by a moving vehicle. Use care when
selecting a good location within the garage. DO
NOT locate the heater where the discharge air
will be directed onto a nearby parked vehicle. DO
NOT store containers of paint, gasoline, or other
ammable liquids in the same area as the heater,
inside or outside the home or structure.
INSTALLATION