6. After 20 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.
The compressor is now ready for use.
Before Each Start-Up:
1. Place On/Auto/Off lever to
"OFF".
2. Pull regulator knob out, turn
counterclockwise until it stops.
Push knob in to lock in place.
3. Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
Risk of Bursting.
Too much air
pressure causes a hazardous risk
of bursting. Check the
manufacturer's maximum pressure
rating for air tools and accessories.
The regulator outlet pressure must
never exceed the maximum
pressure rating.
How to Start:
1. Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2. Pullthe regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.