9
3.3 Installing the Charger
DANGER
Risk of shock. Turn off the power to the charger at the circuit breaker until the installation is completed.
The MaxiCharger AC Elite (commercial) supports both rear entry and bottom entry wiring. Choose the most
appropriate wiring entry for your charger based on the placement of the wiring.
IMPORTANT
Both the rear entry and bottom entry locations are on the left side of the charger. Ensure that you mount
your charger in a location where the power supply wiring can be easily accessed on the left side.
The rear entry cables should be put through the cable inlet holes prior to mounting the charger to the
wall dock.
After the charger is installed, contact Autel support to complete the cloud setup for the charger to ensure
its normal operation.
STEP 1: Placement
1. Find the wall stud nearest to and on the right side of the power
supply wiring using a wall stud finder.
Alternatively, you may find a suitable location on a solid wall.
2. Draw a vertical line of approximately 20" (50 cm) in line with
the wall stud at the approximate height of your mounting.
3. Place the wall dock with the center holes aligned with the
vertical line. Mark the two lower mounting holes (A) and
remove the wall dock.
4. For rear entry wiring, mark the cable exit where the AC input
cable will come out from the wall. Ensure that the cable exit
matches the wall dock notch as per the diagram below.
Loading ...