4
LED Description
LED Description
Power LED
Solid Green: The charger is on.
Not Illuminated: The charger is off.
Flashing Yellow: Data is being transmitted and/or firmware is upgrading.
Solid Yellow: Firmware upgrade has failed.
Solid Blue: Data transmission has failed; will illuminate green in five seconds.
Internet
Connection LED
Solid Green: The charger is connected to the Internet.
Not Illuminated: The charger is not connected to the Internet.
Flashing Green: The charger has joined the DLB (Dynamic Load Balancing)
network.
Charging LED
Solid Blue: An EV is connected.
Flashing Blue: A schedule is active.
Flashing Green: An EV is charging.
Solid Green: A charge session has ended.
Not Illuminated: The charger is not connected.
Solid Yellow: A recoverable error has occurred or it is temporarily disabled by
the server.
Solid Red: An irrecoverable error has occurred. (Please contact support.)
Bluetooth
Connection LED
Flashing Green: The charger is connected to a mobile device via Bluetooth.
Not Illuminated: The charger is not connected via Bluetooth.