Important Safety Instructions
Professiona! Outdoor Grills & Cooktops
WARNING: SAFETYPRECAUTIONS
Do notuse thegrilluntila leektesthas been
performed.
AWARNING:
TEST FOR LEAKS
A complete gas tightness check must
be performed at the installation site.
To prevent fire or explosion hazard, DO NOT
use or permit sources of ignition in the area
while performing a leak test. Perform leak
test outdoors only. Never perform a leak test
with fire or flame. DO NOTSMOKEWHILE
PERFORMINGTHE LEAKTEST.
,,Create a soapy solution of equal parts mild
dishwashing detergent and water.
Check to be sure all controls are in the OFF
position.
Turn on the fuel supply. For natural gas, turn
manual shut-off valve handle 1/4 turn to align
with gas flow. For LID,turn cylinder valve knob
counterclockwise one full rotation.
Apply soap solution generously on all
connections and fittings. See illustrations.
If growing bubbles appear on any connection
point, IMMEDIATELYturn off the gas supply.
To stop a gas leak:
,,Turn on control knobs to release pressure.
Turn controls OFF.
Wash off soapy solution and towel dry.
Tighten the loose joint and perform a new
leak test.
Natural Gas Leak