23
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P
(20, 37).
Flue Type: A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to details in this section for information).
Open Burners
Main Burner Injectors Ø 2.45mm Ø 1.50mm
Pilot Burner ('PF' Option Only) 0.30 0.20
Griddle
Main Burner Ø 2.10mm Ø 1.30mm
Pilot Burner 0.35 0.23
Main Burner Ø 2.40mm Ø 1.40mm
Oven
Pilot Burner 0.35 0.23
Low Fire 0.90mm 0.55mm
Burner Aeration Setting Fully Open 10mm
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Open Burner
Main Burner Injectors Ø 2.30mm Ø 1.40mm
Pilot Burner ('PF' Models Only) 0.30 0.20
Griddle
Main Burner Ø 2.10mm Ø 1.30mm
Pilot Burner 0.35 0.23
Main Burner Ø 2.40mm Ø 1.40mm
Oven
Pilot Burner 0.35 0.23
Low Fire Ø 0.90mm Ø 0.55mm
Burner Aeration Setting Fully open 10mm
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure (*) 9.5 mbar 26 mbar
Gas Regulator Cap Screw
Open Burners
Main Burner Injectors Ø 2.45mm Ø 1.40mm
Pilot Burner ('PF' Option Only) 0.30 0.20
Griddle
Main Burner Ø 2.10mm Ø 1.30mm
Pilot Burner 0.35 0.23
Main Burner Ø 2.40mm Ø 1.40mm
Oven
Pilot Burner 0.35 0.23
Low Fire 0.90mm 0.55mm
Burner Aeration Setting Fully Open 10mm
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa 2.6 kPa
Gas Regulator Cap Screw