On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Before leaving the installation;
1. Check all gas connections for leakage using soapy water or other gas detecting equipment.
2. Carry out a Commissioningcheck of appliance as shown in Installation Section of this manual.
3. Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.