10
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as shown in Gas Conversion Sectionin this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Regulator connections are
3
/
4
" BSP female.
Connection to the appliance is
3
/
4
" BSP male.
(Refer to Specifications section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
5. Connect gas supply to the appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in the Specificationssection.
NOTE: Measure burner operating pressure at manifold test
point with two burners operating at Fullsetting.
8. Turn Offmains gas supply and bleed gas out of
appliance gas lines.
9. Turn Ongas supply and appliance.
10. Verify operating pressure remains correct.
1. Before leaving a new installation;
a. Check the following functions in accordance with operating instructions specified in Operation
section of this manual.
Lighting the Griddle.
Light the Open Burners. (F - Flame Failure Option).
Light the Open Burners. (PF - Pilot and Flame Failure Option).
Check the Low Fire burner operation.
Oven Pilot Ignition.
Oven Main Burner / Thermostat.
Turning the Oven to Stand-ByMode.
Oven Shut Down’.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2. This manual must be kept by owner for future reference, and a record of
Date of Purchase,
Date of
Installation
and
Serial Number of Unit
recorded and kept w ith this manual. (These
details can be found on Rating Plate attached to bottom right hand corner of bottom sill.
Refer to Gas Connectionsection).
NOTE: If it is not possible to get appliance to operate correctly, shut off gas supply and contact
supplier of this appliance.
Fig 2
Manifold
Pressure Test
Point
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.