Loading ...
Loading ...
Loading ...
20
1. Carry out the following:-
Remove griddle plate section and heat shield.
Remove main burner.
Disconnect piezo igniter from mounting
bracket. (For access purposes).
Disconnect pilot supply tube from pilot burner
to access pilot injector.
2. With Main Burner removed, ensure aeration gap is adjusted
for type of gas being used as shown inGas Specifications
Tablesat rear of this section.
3. Remove pilot and main injectors and replace with correct size
injectors as shown inGas Specifications Tablesat rear of this
section.
4. Refit the following:-
Re-connect pilot supply tube to pilot burner.
Re-connect piezo igniter to mounting bracket.
Refit main burner, gas control heat shield and griddle plate to cooktop.
5. Re-light main burners and check flame size on Lowflame position.
Adjust low fire adjustment screw on open burner gas control
valves to obtain desired flame size.
NOTE: The 'Low Fire Screw' should be sealed with coloured paint on
completion of low fire adjustment.
1. Carry out the following:-
Remove lower lintel at front of oven.
Open oven door and remove sole plate(s).
Remove main burner.
Disconnect pilot supply tube from pilot burner to
access pilot injector.
2. With Main Burner removed, ensure aeration gap is adjusted
for type of gas being used as shown inGas Specifications
Tablesat rear of this section.
Main Burner Injector
Pilot Supply
Tube
Pilot Burner
Piezo Igniter
Low Fire Screw
Burner Adjustment Screw
Aeration Slide
Burner Adjustment Screw
Main Burner
Main Burner Injector
Pilot Burner
Thermocouple
Aeration Slide
Loading ...
Loading ...
Loading ...