SDS5000X Series Digital Oscilloscope User Manual
 Falling Edge— Trigger on signals less than the Threshold setting value.
 Touch Threshold to set the threshold by the universal knob or
virtual keypad. The range of value is related to the number of
Data Bits.
16.9.3 I2S Serial Decode
The configuration of I2S decoding is similar to that of I2C decoding.
In the list view:
 Time— The horizontal offset of the current data frame head relative
to the trigger position.
 Type— Channel type, left channel is represented by "Left CH" and
right channel is represented by "Right CH".
 Data— Data bytes
 Error— Error