HEATER INSTALLATION
2000W & 3000w models must be installed with the minimum installation clearances shown in below diagrams.
2000W & 3000W models are supplied with short mounting brackets to be used for both ceiling & wall mounting.
INSTALLATION CLEARANCES
FOR 4000W & 6000W MODELS
4000W & 6000W models must be installed with the minimum installation clearances shown in below diagrams.
4000W & 6000W models are supplied with long mounting brackets to be used for both ceiling & wall mounting.
Alternatively, short mounting brackets can be used for wall mounting of the 4000W & 6000W models to position
the heater closer to the wall. Short mounting brackets must be purchased separately.
250
300
300
45°
120
45°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
300
330
450 300
30°
2400
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
1800
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
30
°
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
Heater MUST be installed so that the tube elements are
horizontal. Failure to do this will cause the heating element
within the tube to sag and cause premature burnout.
Installing vertically will void the manufacturers warranty.
INSTALLATION CLEARANCES
FOR 2000W & 3000W MODELS
!
!
WARNING
DO NOT MOUNT THE HEATER VERTICALLY!
For outdoor installation heater must be mounted with
face of heater angled down.
For longest product life & to maintain product
appearance mount heater under cover & protect from
rain & weather whenever possible.
www.bromic.com/heating-au
7
! WARNING
MINIMUM DISTANCE BETWEEN
HEATERS MEASURED FROM EDGE OF
HEATER MUST BE AT LEAST 500mm
! WARNING
MINIMUM DISTANCE BETWEEN
HEATERS MEASURED FROM EDGE OF
HEATER MUST BE AT LEAST 500mm
The฀฀stated฀clearance฀to฀
combustible฀฀materials฀represents฀
surface฀฀temperature฀of฀65
o
C฀
above฀฀room฀temperature.฀
Building฀material฀with฀a฀low฀heat฀
tolerance฀(such฀as฀plastic,฀vinyl฀
siding,฀canvas,฀tri-ply฀etc.)฀may฀
subject฀to฀degradation฀at฀lower฀
temperature.฀It฀฀is฀the฀installer's฀
responsibility฀to฀assure฀that฀
adjacent฀materials฀are฀protected.