WARNING
This Heater MUST be permanently Installed and hard
wired by an authorised/licenced person. Do Not perform
maintenance, or carry out installation or assembly
procedure while electrical power is switched on.
1.Check product label for correct voltage and wattage -
Make sure power source conforms to the heaters require-
ments.
2.Junction box has a Ø22mm hole to suit M20 or PG13.5
cord grip. Install cord grip with minimum rating of IPX4
to
maintain the IPX4 rating of the heater. Cord grip must
have minimum temperature rating of 105°C.
3.Use appropriate power supply cables for the heaters’
voltage and wattage with minimum temperature rating of
105°C. The fixed wiring must be positioned away from &
protected from the enclosure of the heater.
4.Make electrical connections in accordance with local
elec-trical code regulations. For outdoor installation all
con-nections must be made in accordance with local
electrical code regulations for outdoor wiring. Only use
wiring com-ponents approved for outdoor use with
minimum IPX4
WARNING
!
rating. For 2000W & 3000W models the junction box has
one loop of cable. Cut the loop and use the two ends for
the active and neutral connections for the element. For
4000W & 6000W models the junction box has two loops
of cable. Cut the cable loop marked black and use the
two ends for the active & neutral connections for the first
element. Cut the unmarked cable loop and use the two
ends for the active & neutral connections for the second
element. Earth ground wire screw is located in the end of
junction box.
5. After installation, the distance between live parts and
earth (or earthed metal) should not be less than 2.5 mm.
The distance between live and neutral terminal should not
be less than 2.0 mm.
6. Assemble the junction box cover & gasket. Ensure that
the junction box cover gasket (supplied with unit) is
installed to maintain the IPX4 water ingress protection
rating of the heater. Failure to install correctly will void the
manufacturer’s warranty
ELECTRICAL INSTALLATION
6
1
2
4
www.bromic.com/heating-au
12
ELECTRICAL SHOCK HAZARD! Serious injury or death may
occur. Disconnect from electrical supply before installing or
servicing this heater. Read and follow installation clearance
requirements outlined in this manual. The Appliance MUST
be connected to a properly grounded electrical source.
IMPORTANT: Electronic dimmer controls generate heat
during operation. For Bromic heaters installed Bromic
Smart-Heat Electric Wireless Dimmer 2620276-1 or ON/
OFF Control 2620275-1 it is essential to ensure dimmers
are mounted in a clean, dry and well ventilated position
with clearance on all sides. It must be ensured the
dimmers are not installed in a confined space, close to
other heat generating appliances or in the case of a
multi-dimmer installation, not too close together.
Dimmers must remain cool at all times.
Please consult Bromic dimmer installation instructions
for further details or for further questions please contact
Bromic technical support services.