WARNING: Any safety screen or guard removed for servicing an appliance must be
replaced prior to operating the heater.
WARNING: When the appliance is installed directly on carpeting, tile or other combustible
material, other than wood ooring, the appliance shall be installed on a metal or wood panel
extending the full width and depth of the appliance.
WARNING: Do not attempt to access or change the setting of the fuel selection means.
Access to and adjustment of the fuel selection means must only be a performed by a
qualied service person when connecting this appliance to a specied fuel supply at the
time of installation.
Change of the selector setting to other than the fuel type specied at the time of installation
could damage this appliance and render it inoperable.
The installer shall replace the access cover before completing the installation and operating
this appliance.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
CAUTION - FOR YOUR SAFETY
- Do not store or use gasoline or other ammable vapors and Iiquids in vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or
the gas supplier.
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.
Refer to Air For Combustion and Ventilation section on page 8-10 of this manual.
This appliance may be installed in an aftermarket, permanently located manufactured
(mobile) home, where not prohibited by local codes. This appliance is only for use with
propane or natural gas. This appliance is equipped with a simple means to switch between
propane and natural gas. Field conversion by any other means including the use of a kit is
not permitted.