Cobra CW2H-DD 1200mm Gas Waterless Wok with 2 Duckbill burners

Installation Operation Manual - Page 7

For CW2H-DD.

PDF File Manual, 23 pages, Read Online | Download pdf file

CW2H-DD photo
Loading ...
Loading ...
Loading ...
5
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at the manifold pressure test point with the main burner
operating at 'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, apart from
when converting between gases, if required.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Burner Ratings
- C (Chimney Burner)
95 MJ/hr 95 MJ/hr N/A
- D (Duckbill Burner)
105 MJ/hr 105 MJ/hr 105 MJ/hr
Model Ratings
Total Nominal Hourly
Gas Consumption
CW1H-C
95 MJ/hr 95 MJ/hr N/A
CW1H-D
105 MJ/hr 105 MJ/hr 105 MJ/hr
CW2H-CC
190 MJ/hr 190 MJ/hr N/A
CW2H-CD
200 MJ/hr 200 MJ/hr N/A
CW2H-DD
210 MJ/hr 210 MJ/hr 210 MJ/hr
CW3H-CCC
285 MJ/hr 285 MJ/hr N/A
CW3H-CCD
295 MJ/hr 295 MJ/hr N/A
CW3H-CDD
305 MJ/hr 305 MJ/hr N/A
CW3H-DDD
315 MJ/hr 315 MJ/hr 315 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.0 kPa 2.65 kPa
Gas Connection
¾” BSP Male