NOTE: (*) Measure burner operating pressure at the manifold pressure test point with the main burner
operating at 'High Flame' setting. Operating pressure is ex-factory set, through the appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. Refer
to the details in this section for further details.
Main Burner Injectors
WC (Wok Chimney)
Ø 0.95mm Ø 0.60mm
WD (Wok Duckbill)
Ø 1.25mm Ø 0.75mm
Main Burner Injectors (Qty)
WC (Wok Chimney)
24 24
WD (Wok Duckbill)
18 18
Main Burner Primary Air
WC (Wok Chimney)
5.0mm 6.0mm
WD (Wok Duckbill)
6.0mm 6.0mm
Pilot Burner Injector
0.35mm
Fully In (C.W)
0.35mm
Fully In (C.W)
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 1.00 kPa 2.65 kPa
Gas Regulator Cap Screw
Main Burner Injectors
WC (Wok Chimney)
Ø 0.95mm N/A
WD (Wok Duckbill)
Ø 1.25mm Ø 0.70mm
Main Burner Injectors (Qty)
WC (Wok Chimney)
24 N/A
WD (Wok Duckbill)
18 18
Main Burner Primary Air
WC (Wok Chimney)
5.0mm N/A
WD (Wok Duckbill)
6.0mm 6.0mm
Pilot Burner Injector
0.35mm
Fully In (C.W)
0.35mm
Fully In (C.W)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.00 kPa 2.65 kPa
Gas Regulator Cap Screw
Main Burner Injectors
WC (Wok Chimney)
Ø 0.95mm Ø 0.60mm N/A
WD (Wok Duckbill)
Ø 1.25mm Ø 0.75mm Ø 0.70mm
Main Burner Injectors (Qty)
WC (Wok Chimney)
24 24 N/A
WD (Wok Duckbill)
18 18 18
Main Burner Primary Air
WC (Wok Chimney)
5.0mm 6.0mm N/A
WD (Wok Duckbill)
6.0mm 6.0mm 6.0mm
Pilot Burner Injector
0.35mm
Fully In (C.W)
0.35mm
Fully In (C.W)
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
1.00 kPa 2.65 kPa
Gas Regulator Cap Screw