Cobra CW2H-DD 1200mm Gas Waterless Wok with 2 Duckbill burners

Installation Operation Manual - Page 15

For CW2H-DD.

PDF File Manual, 23 pages, Read Online | Download pdf file

CW2H-DD photo
Loading ...
Loading ...
Loading ...
13
4. On the Control Panel,
turn the Water Valve anti
-clockwise to the ‘On’
position, water will flow
from the Water Filling
Arm.
5. When the Water Filling
Arm is not in use, move the arm back against the
splashback to prevent damage to the arm and
exposure to the heat from the Wok burners.
1. Check gas supply is turned ‘On’ at the mains
supply.
2. Ensure that the Main Burner Gas Valve is in the
‘Off’ position.
3. Rotate the Pilot Burner Gas Valve anti-clockwise
to the ‘On’ position.
4. Press and hold the Gas Safety Valve depressed
and manually light the Pilot Burner.
5. Keep holding the Gas Safety Valve depressed
for 30 seconds after the pilot burner is lit, to allow
the thermocouple to warm up.
6. Release the Gas Safety Valve, the pilot burner
should remain alight.
7. If the pilot burner does not ignite, repeat Items 3
to 6 above.
1. Turn ‘On’ the Main Burner Gas Valve anti-
clockwise to the setting required to suit the
cooking requirements. The main burner will
ignite.
1. Turn the Main Burner Gas Valve anti-clockwise to
the ‘Off’ position, the Main Burner will extinguish.
2. The Pilot Burner will still be ’On’.
1. Turn the Pilot Burner Gas Valve clockwise to the
‘Off’ position, the Pilot Burner will extinguish.
2. Turn ‘Off’ the gas supply at the mains supply.
Water Valve
Loading ...
Loading ...
Loading ...