Recommended HVAC System Installation
DUCTING TO HVAC SYSTEMS
The recommended installation draws air from a dedicated indoor air return and ducts the supply of the
dehumidier to the air supply of the existing HVAC system. Utilize the optional fresh air ventilation duct to
provide outside air.
• Install a dedicated 10" air return for the Dehumidier from a central area of the structure.
Install an insulated duct from outside to the 6" collar of the Dehumidier to provide fresh air
ventilation (optional).
Duct the supply of the Dehumidier to the supply of the existing HVAC system with a backdraft damper.
If the existing system has multiple returns, instead of installing a dedicated return to the
Dehumidier, it is possible to select one to disconnect from the existing HVAC system and use it for the
dedicated Dehumidier return. Select a return from a central location in the house that is always open to
the rest of the structure. DO NOT use a return from a room where doors are kept closed.
DO NOT locate return in a bathroom or kitchen.
Control should be located remotely from the dehumidier and placed in a central location.
• Please visit our website at www.Broan-NuTone.com for more installation options.
Santa Fe
Supply
Air Handler
HVAC Supply
Dedicated Ultra-Aire 90 Return to A/C Supply
HVAC Return
Fresh Air Intake
(Optional)
Motorized
Damper
Indoor
Air Return
Backdraft
Damper
Dedicated Return to HVAC Supply
Supply