The Dehumidier plugs into a common grounded 115 VAC outlet. Locate the dehumidier in an area where the
cord’s length (9') easily reaches a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity. If used
in an area that may become wet, a GFCI protected circuit is recommended. Consult local electrical codes for
further information.
A variety of control devices can be used with this dehumidier. The control is to be located remotely from the
dehumidier and placed in the space to be conditioned. A low voltage (24 Volt) control MUST be used with the
Dehumidier and MUST be connected with low voltage (18-22 gauge) thermostat wire.
ELECTRICAL REQUIREMENTS
CAUTION!CAUTION!
DO NOT ALLOW THE 24V TERMINAL TO CONTACT THE COM/DMPR TERMINALS ON THE
DEHUMIDIFIER OR DAMAGE TO THE TRANSFORMER WILL RESULT.
Electrical Precautions
Do not install the control where it may not accurately sense the relative humidity such as near HVAC
supply registers, near exterior doors, on an outside wall, near a window, or near a water source.
The screw terminals on the Dehumidier and the control are labeled to prevent confusion.
Be sure to consult the electrical schematic in the CONTROLS Section (page 12) of this manual or inside
the access panel of the Dehumidier before making control connections.
WARNING!WARNING!
THE REMOTE CONTROLS OF THE DEHUMIDIFIER ARE POWERED BY A LOW VOLTAGE CIRCUIT (24
VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
CAUTION!CAUTION!
SOME OF THE SCREW TERMINALS ON THE DEHUMIDIFIER MAY NOT BE USED WITH CERTAIN
CONTROLS AND SHOULD BE LEFT UNCONNECTED.