5
Gas Supply
BEFORE INSTALLATION
ROOM VENTILATION
An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the appropriate national and local standards. Exhaust hood operation
may affect other vented appliances; in each case it shall be installed in conformity with the
appropriate national and local standards.
TYPE OF GAS
This appliance is shipped from the factory for use with natural gas. For use with liquid
propane gas, please follow the conversion procedure described on
page 14. A step by
step conversion procedure is also included with each set of liquid propane gas orifices.
GAS PRESSURE
The maximum inlet gas supply pressure incoming to the gas appliance pressure
regulator is 1/2 PSI.
The minimum gas supply pressure for checking the regulator setting shall be at least
1˝ W.C. (249 Pa) above the inlet specified manifold pressure to the appliance. This
operating pressure is 4˝ W.C. (1.00kPa) for natural gas and 10˝ W.C. (2.75 kPa) for
liquid propane gas.
Range top requires 1”- 6” side wall spacing above the counter height for proper
combustion. Please review specific model installation instructions for required
dimensions; 30”-36” between the range top and bottom of the range hood above,
1/4” for sides below countertop height.