13
Gas Connection
PRESSURE REGULATOR
Since service pressure may fluctuate with local demand, every gas cooking appliance
must be equipped with a pressure regulator on the incoming service line for safe and
efficient operation.
•
Pressure Regulator
The pressure regulator shipped with the appliance has two female 1/2” NPT threads.
• The regulator shall be installed properly in order to be accessible when the appliance
is installed in its final position.
• Manifold pressure should be checked with a manometer and comply with the values
indicated below.
Natural gas — 4.0” W.C.P.
Liquid propane gas — 10.0” W.C.P.
• Incoming line pressure upstream from the regulator must be 1˝ W.C.P. higher than the
manifold pressure in order to check the regulator.
• The regulator used on this range can withstand a maximum input pressure of 1/2
PSI (13.8˝ W.C. or 3.5 kPa). If the line pressure exceeds that amount, a step down
regulator is required.
• The appliance, its individual shut-off valve, and the pressure regulator must be
disconnected from the gas line during any pressure testing of that system at pressures in
excess of 1/2 PSI (13.8˝ W.C. or 3.5 kPa).
WARNING
Before carrying out this operation, disconnect the appliance from gas and
electricity. Gas conversion shall be conducted by a factory-trained
professional.