40
Problem Solution
The unit doesn’t
start.
Make sure the door is latched shut.
Be sure the power cord is plugged into a live electrical
outlet.
Check the home’s circuit breaker and fuses.
Press the Start/Pause button again if the door is opened
during the cycle.
The unit doesn’t
heat.
Check the home’s circuit breaker and fuses.
Select a heat setting other than Air flu and check that
the Temp selection is not on “No heat”
On a gas dryer, check that the gas supply is on.
Clean the lint filter and exhaust duct.
Dryer may have moved into the cool-down process of
the cycle.
Doesn’t dry.
Check all of the above, plus...
Be sure the exhaust hood outside the home can open
and close freely.
Check exhaust system for lint buildup. Ducting should be
inspected and cleaned annually.
Use a 4” rigid metal exhaust duct.
Do not overload. 1 wash load = 1 dry load.
Sort heavy items from lightweight items.
Large, bulky items like blankets or comforters may
require repositioning to ensure even drying.
Load may be too small to tumble properly. Add a few
towels.
After cleaning the exhaust hood, check that the flapper or louvers
move freely.
Reassemble the exhaust duct and hood, checking that the joints are
secure and sealed.
Operate the dryer and verify that the exhaust air is not obstructed in
the vent and that there are no leaks in the system.
The outside exhaust hood should be cleaned more frequently to
ensure proper operation.
TROUBLESHOOTING
CHECK THESE SOLUTIONS IF YOUR DRYER...
If your dryer has any of the following problems, you can check the solutions listed
below before making a service call. This will help you save time and money.
Dryer
Safety
Operation
Requirements
Parts and
Features
Installation
Instructions
Dryer Care
Troubleshooting AppendixDryer Use
Loading ...
Loading ...
Loading ...