TP-7092 2/21 17Section 1 Descriptions and Service Views
1.7 OnCue Plus Generator
Management System
The Kohler OnCue Plus Generator Management
System is now included with the generator set. The
OnCue Plus System allows monitoring and control of
your generator set from your home or other location with
Internet access using a computer or mobile device.
OnCue Plus can be configured to send email or text
message notifications in the event of a generator set
fault.
You can also use Google Assistant or Amazon Alexa
and your smart device to control your generator. Use
voice commands to check your generator’s status,
check for active alerts, and start or stop an exercise.
See the OnCue Plus User Guide, TP- 7006, for simple
setup instructions and voice commands
OnCue Plus Wireless is also available. OnCue Plus
Wireless works with the customer’s wireless ethernet
router and does not require the installation of a network
cable between the generator set and the customer’s
router/modem.
1.8 Accessories
The following optional accessories are offered for the
generator sets.
1.8.1 Cold Weather Package Kit
Heater kits are recommended for improved cold starting
in locations where the ambient temperature drops below
0C (32F).
The cold weather package kit includes:
Alternator brush cover
Battery heater
Breather tube heater
Fuel regulator heater
Oil heater
Oil pressure sensor cover
3-way extension cord for power connection
The heaters require a continuous source of AC power.
See the generator set Installation Manual and the
installation instructions provided with the kits for more
information.
1.8.2 Programmable Interface Module
(PIM)
The optional Programmable Interface Module (PIM)
provides two programmable inputs and six
programmable dry contact outputs for connection to
customer-supplied equipment. The outputs are
controlled by the RDC2 controller, and can also be
controlled remotely using OnCue Plus.
The PIM is mounted in a NEMA 3R aluminum enclosure,
which can be mounted indoors or outdoors. See the
installation instructions provided with the PIM.
1.8.3 Load Management
Two optional load management devices are available
for use with single-phase generator sets and a model
RXT or RDT transfer switch.
The optional Load Shed Kit mounts inside a model
RDT or RXT transfer switch.
The combined interface/load management board is
available for the Model RXT transfer switch.
The load management devices provide an automatic
load management system to comply with Section 702.5
of NEC 2008. The installer is responsible for ensuring
that the power system installation complies with all
applicable state and local codes.
Note: The load management devices are only
compatible with single-phase generator sets.
The load management device automatically manages
up to six residential loads. Two relays are provided to
control two independent air conditioner loads. Up to four
power relay modules can be connected for
management of non-essential secondary loads.
The load management device is controlled by the RDC2
controller. The load on the generator set is monitored,
and loads are added or shed in the order of their priority.
See the installation instructions provided with the load
shed kit or the Model RXT Operation and Installation
Manual for more information.