Overload indicator (red)
When the overload indicator is on, it indicates that the generating set is overload and then the AC
protector works. It will stop the output of generating set to protect the electric equipment and the
generating set itself. At this time, the running indicator (green) is off and the overload indicator (red) is on,
but the engine is still in running state.
When the generating set has no output and the overload indicator is on, please take the following steps:
1. Lower the total power of the connected electric devices to the rated output range of generating set.
2. Check the air intake for impurities and check the control parts for abnormal situation. Handle
immediately if necessary.
3. Press the reset button.
Running indicator (green)
The running indicator lights up when generating set starts and has normal output.
Oil alarm lamp (yellow)
When the oil level drops below the lower limit, the oil protection system will stop the engine
automatically and oil alarming lamp will blink by pulling the recoil starter. The engine will not run until
the oil has been filled to the proper level.
Note: If engine flames out or fails to start, turn the combination switch to “RUN position and then pull
the recoil starter. If the oil alarming lamp lights up, it shows lack of oil. Please add appropriate oil and
restart the engine.