CLEANING AND MAINTENANCE
17
REDUCING GAS FLOW
1. Ignite the burner that is to be adjustment and turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For LPG (butane-pro
pane) turn the screw clockwise. For the naturel gas, you should turn the screw counter- clockwise once.
“The normal length of a straight flame in the reduced position should be 6-7 mm.
4. If the flame is higher than the desired position, turn the screw clockwise. If it is smaller turn
anticlockwise.
5. For the last control, bring the burner both to high-flame and reduced positions and check whether the
flame is on or off. Depending on the type of gas tap used in your appliance the adjustment screw position
may vary. To adjust your oven acc. to the gas type, make the adjustment for reduced flame carefully by
turning with a small screwdriver as shown below on the screw in the middle of the gas cocks as well as
nozzle changes. (figure 6 and 7)