Craftsman 113213853 15" drill press

User Manual - Page 6

For 113213853.

PDF File Manual, 28 pages, Download pdf file

Loading ...
Loading ...
Loading ...
"" r
motor specifications and emectrmcaaequirements
MOTOR SPECIFICATIONS This power tool Is equipped with a3-conductor cord
This drill press is designed to use a 1725 RPM motor and grounding type plugwhich has a groundingprong,
only. Do not use any motor that runs faster than 1725 approved by Underwriters'Laboratories and the Cana-
RPM. It is wired for operation on 110-120 volts, 60 Hz. dian Standards Association.The ground conductorhas
alternating current, a green jacket and is attached to the tool housing at
WARNING: To avoid injury from unexpected start-
up, do not use blower or washing machine motors
or any motor with an automatic reset overload pro-
tector.
CONNECTING TO POWER SOURCE OUTLET
This machine must be grounded while in use to protect
the operator from electric shock.
Plug power cord into a 110-120V properly grounded
type outlet protected by a 15-amp. dual element time
delay or Circuit-Saver fuse or circuit breaker.
NOT ALL OUTLETS ARE PROPERLY GROUNDED.
IF YOU ARE NOT SURE THAT YOUR OUTLET, AS
PICTURED BELOW, IS PROPERLY GROUNDED,
HAVE IT CHECKED BY A QUALIFIED ELECTRI-
CIAN.
WARNING: Do not permit fingers to touch the ter-
minals of plugs when installing or removing the
plug to or from the outlet.
WARNING: If not properly grounded this power
tool can incur the potential hazard of electrical
shock, particularly when used in damp locations,
in proximity to plumbing. If an electrical shock oc-
curs there is the potential of a secondary hazard
such as your hands contacting the cutting tool.
If power cord is worn or cut, or damaged in any
way, have it replaced immediately to avoid shock
or fire hazard.
3.PRONG
PLUG
one end and to the ground prong =nthe attachment
plug at the other end.
This plug requires a mating 3-conductor grounded type
outlet as shown,
If the outlet you are planning to use for this power tool
is of the two prong type, DO NOT REMOVE OR ALTER
THE GROUNDING PRONG IN ANY MANNER. Use
an adapter as shown and always connect the grounding
lug to known grown.
Itis recommended that you have a qualified electrician
replace the TWO prong outlet with a properly grounded
THREE prong outlet.
An adapter as shown below Js available for connecting
plugs to 2-prong receptacles.
WARNING: The green grounding lug extending
from the adapter must be connected to a permanent
ground such as to a properly grounded outlet box.
GROUNDING LUG
\
SCR_,,_
3-PRONG
PLU
\
ADAPTER
MAKE SURE THIS IS
CONNECTED TO A
KNOWN GROUND
2-PRONG
RECEPTACLE
GROUNDING
PRONG
ALWAYS USE A
PROPERLY GROUNDED
OUTLET
If your unit is for use on less than 150 volts, it has a
plug that looks like the above.
NOTE: The adapter illustrated is for use only if you
already have a properly grounded 2-prong receptacle.
Adapter is not allowed inCanada by the Canadian Elec-
trical Code,
The use of any extension cord wilt cause some loss of
power. To keep this to a minimum and to prevent over-
heating and motor burn-out, use the table below to
determine the minimum wire size (A.W.G.) extension
cord. Use only 3 wire extension cords which have 3-
prong grounding type plugs and 3-pole and 3-pole re-
ceptacles which accept the tools plug.
ExtensionCordLength WireSizeA.W.G.
Upto-lOOFt. 16
100-200 R. 14
200-400 R. 10
Loading ...