1. Remove the 2 screws and remove the protective
cover. The main fuse is in a holder behind the
battery.
2. Pull the fuse from the holder.
3. Replace the broken fuse with a new fuse of the
same type, flat pin 15 A.
4. Replace the cover.
If the main fuse breaks again a short period after you
replace it, there is a short circuit. Repair the short circuit
before you operate the product again. Let an approved
service agent help you.
To charge the battery
Charge the battery if it is too weak to start the
engine.
Use a standard battery charger.
CAUTION:
Do not use a boost
charger or start booster. That will cause
damage to the electrical system of the
product.
Charge for 4 hours at maximum 3A.
Always disconnect the charger before starting the
engine.
When the battery is charged, connect the red cable
to the POSITIVE battery terminal (+) and the black
cable to the NEGATIVE battery terminal (-). Make
sure that the red (+) cable is drawn behind the black
(-) cable.
To do an emergency start of the engine
If the battery is too weak to start the engine, you can use
jumper cables to do an emergency start. This product
has a 12 V system with negative ground. The product
that is used for the emergency start must also have a 12
V system with negative ground.
To connect the jumper cables
WARNING: Risk of explosion because
of explosive gas that comes from the
battery. Do not connect the negative
terminal of the fully charged battery to or
near the negative terminal of the weak
battery.
CAUTION: Do not use the battery of
your product to start other vehicles.
1. Remove the engine cover.
2. Remove the cover for the battery case.
3. Connect one end of the red cable to the POSITIVE
battery terminal (+) on the weak battery (A).
B
A