7
Installation - C12000 Controller
The C12000 Controller can be placed upright on a
table or shelf, standing on its four feet. It also can be
custom installed in a piece of furniture or cabinet
of your choice. The four feet may be removed from
the bottom of the unit when it is custom installed as
outlined below. The four feet together with the mount-
ing screws should be retained for possible future use
if the C12000 Controller is removed from the custom
installation and used free standing. The required panel
cutout, ventilation cutout and unit dimensions are
shown.
Always provide adequate ventilation for your
C12000 Controller. Cool operation ensures the longest
possible operating life for any electronic instrument.
Do not install the Controller directly above a heat
generating component such as a high powered ampli-
fier. Also do not stack the C12000 Preamplifier on top
of the C12000 Controller. If all the components are
installed in a single cabinet, a quiet running ventila-
tion fan can be a definite asset in maintaining all the
system components at the coolest possible operating
temperature.
A custom cabinet installation should provide the
following minimum spacing dimensions for cool
operation.
Allow at least 6 inches (15.2cm) above the top, 2
inches (5.1cm) below the bottom and 1 inch (2.5cm)
on each side of the Controller, so that airflow is not
obstructed. Allow 20 inches (50.8cm) depth behind the
front panel. Allow 1-7/16 inch (3.7cm) in front of the
mounting panel for knob clearance. Be sure to cut out
a ventilation hole in the mounting shelf according to
the dimensions in the drawing.
Balanced 1
70%
C 1 2 0 0 0 CO N T RO L LE R
SETUP
MUTE
RESET
ADJUS T
VOLUME
TRIM
INPUT
MENU
STANDBY / ON
C12000 Controller
Front Panel
Custom Cabinet Cutout
Cutout
Opening
for
Ventilation
Cutout Opening
for Ventilation
Support
Shelf
Chassis
Spacers
C12000 Controller
Side View
in Custom Cabinet
Note: Center the cutout Horizontally
on the unit. For purposes of clarity,
the above illustration is not drawn to scale.
C12000 Controller
Bottom View
in Custom Cabinet
2-
7/8"
7.3cm
17-3/16"
43.66cm
Cutout Opening for Custom Mounting
Cabinet Front Panel
10-3/4"
27.3cm
Opening for Ventilation
Cabinet
Front
Panel
6"
15.2cm
Opening
for Ventilation
15-1/16"
39.6cm
8-1/8"
23.2cm
13-1/8"
33.3cm
12-5/16"
31.3cm
1-1/8"
2.9cm
15-1/16"
38.3cm
Loading ...
Loading ...